00000097.gif Fujitsu M2512A : Switch Settings

PCA Layout All configurations marked * are default settings.

Switch SW1


Select SCSI ID

Keys        1           2           3           SCSI ID     
                                                            
	    OFF*        OFF*        OFF*        0           
                                                            
            OFF         OFF         ON          1           
                                                            
            OFF         ON          OFF         2           
                                                            
            OFF         ON          ON          3           
                                                            
            ON          OFF         OFF         4           
                                                            
            ON          OFF         ON          5           
                                                            
            ON          ON          OFF         6           
                                                            
            ON          ON          ON          7           
                                                            

SCSI bus parity check


Key 4       ON*         Enabled                                     
            OFF         Disabled                                    
                                                                    

Synchronous data transfer request mode

Key 5       ON          Enabled                                     
            OFF*        Disabled                                    
                                                                    

Changing this function will not affect asychronous transfers.

Device type

Key 6       ON          Optical memory device (INQ = '07')          
            OFF*        Direct access device (INQ = '00')           
                                                                    

This determines what response the drive will give to an INQUIRY command.

Spindle automatic stop mode

Key 7       ON*         Enabled                                     
            OFF         Disabled                                    
                                                                    

With the disk loaded, the spindle continues to rotate until the START/STOP unit command instructs the spindle to stop. The spindle automatic stop function comes into operation when the host does not issue a command for about 30 minutes. If the host issues a command after the spindle has stopped then the spindle will start up and process the command without posting a not ready state. 00000060.gif This function greatly reduces the amount of dust that can collect on the disk, however it is not suitable for a system which requires a quick response as the spindle takes several seconds to get up to speed. 00000060.gif The access monitoring time and the function itself can be changed or enabled via a MODE SELECT command.

LED mode

Key 8       OFF*        Mode 1                                                                           
            ON          Mode 2                                                                           
                                                                                                         

Mode 1 The LED lights when drive is positioning, reading, writing, loading, ejecting and during the power on test. At power-on test the LED will blink at 1 second intervals after detecting an error or 2 second intervals having detected a thermal error.

Mode 2 The LED lights only on power-on test and whilst waiting. Error detection and reporting is as for Mode 1.

Switch Bank SW2


Write cache mode.

Key 1       ON          Enabled        
            OFF*        Disabled       
                                       

When enabled, a write error is reported at the completion of the next command. This can speed up write times but do ensure your system will respond correctly by knowing what data to resend.

Key 2       OFF*        Not Used       
                                       

Mac mode

Key 3       ON          Enabled        
            OFF*        Disabled       
                                       

Because of the differing ways that both Apple Macintosh and PC hosts respond to the status of the drive, set this switch accordingly. Mac mode ON will disable the 'UNIT ATTENTION' reporting on power up and media change.

Verify after write mode

Key 4       ON          Disabled       
            OFF*        Enabled        
                                       

When disabled, the performance of a write operation is improved by approximately 20%, however data integrity cannot be guaranteed.

SCSI level

Key 5       ON          SCSI-2 mode                                                        
            OFF*        SCSI-1 mode (Compatible with M2511A)                               
                                                                                           

SAVE DATA POINTER message mode

Key 6       OFF*        SAVE DATA POINTER message posted before sending DISCONNECT message                                 
            ON          No message sent before DISCONNECT message                                                          
                                                                                                                           
Key 7       OFF*        Not used                                                                                           
                                                                                                                           
Key 8       OFF*        Factory examination mode                                                                           
                                                                                                                           

Terminal CNH 1


SCSI Terminating Power

1-2          3-4          Function                                                                     
                                                                                                       
SHORT*       SHORT*       Power is supplied from the drive to both the terminating resistor pack and   
                          the TERMPWR pin on the SCSI bus. (Pin 26)                                     
                                                                                                       
OPEN         SHORT        The TERMPWR pin is not used. Power is supplied from the drive to the drive's 
                          active terminator.                                                            
                                                                                                       
SHORT        OPEN         Power is not supplied to the terminating resistor from the drive, only from  
                          the TERMPWR pin.                                                              
                                                                                                       
OPEN         OPEN         Not used                                                                     
                                                                                                       

SCSI Active Terminator Module on Drive PCA

5-6          SHORT*       Enabled                                                                     
             OPEN         Disabled                                                                    
                                                                                                      

Note that there is no removable terminating resistor module on this drive. All termination functions are set through this terminal.

Terminal CNH 2


External operator panel connector

Pin          Signal                                             
                                                                
1            CTGIN (Cartridge in)                               
                                                                
2            -ID2 (bit value 4)                                 
                                                                
3            +LED (+5V)                                         
                                                                
4            -ID1 (bit value 2)                                 
                                                                
5            -LED                                               
                                                                
6            -ID0 (bit value 1)                                 
                                                                
7            EJSW (Eject switch)                                
                                                                
8            COMMON 0                                           
                                                                
9            Device type mode                                   
                                                                
10           Spindle automatic stop mode                        
                                                                
11           Macintosh mode                                     
                                                                
12           COMMON 1                                           
                                                                
13           Verify Mode                                        
                                                                
14           SCSI type 0                                        
                                                                
15           SCSI terminating resistor                          
                                                                
16           0V (Ground)                                        
                                                                

The cable length to the operator panel should not exceed 30 centimetres

COMMON 0 and COMMON 1 are control signals and should not run to ground.

00000110.gif