Functional Specifications
No. data recording tracks :
B /H series : 18
K series : 36 (18 track serpentine)
Data recording method : GCR (DD-NRZI 18Tr)
Recording density :
B /H series : 37,871 bpi
K series : 75,742 bpi
Recording capacity : *
B /H series : 600MB (with EDRC)
K series : 1200MB (with EDRC)
2400MB (with EDRC and double length tape)
IBG length : 2.0 millimetres
Tape speed : 2 metres/second
Load/Unload time : 13 seconds typical
Rewind time :
Standard length tape : 65 seconds max.
Double length tape : 120 seconds max.
Host Interface :
B /B1 /H /H1 /K /K1 type : SCSI-2, single ended
BD /BD1 /HD /HD1 /KD /KD1 type : SCSI-2, differential
Host interface data tranfer rate :
Asynchronous : 3.0 MB/second
Synchronous : 4.0 MB/second
Drive/Controller : 3.0 MB/second
Data buffer capacity : 2MB
Noise : 50dB or less
Weight : 12kg or less
(*) This is not the minimum guaranteed value but the standard recording capacity measured for a block length of 24KB. The recording capacity is also dependant on the tape length and tape quailty. (1MB = 1 × 10^6 bytes)
IBM is a registered trademark and IDRC is a trademark of International Business Machines Corporation.
Physical Specifications
Dimensions :
Height × Width × Depth
M2483B /BD /H /HD : 127mm × 217mm × 400mm
M2483K /KD : 127mm × 217mm × 380mm
M2485B /BD /H /HD /K /KD : 282mm × 222mm × 440mm
M2485B1 /BD1 /H1 /HD1 /K1 /KD1 : 282mm × 222mm × 650mm
Weight : kg. (lbs)
M2483B /BD /H /HD : 12 (26.4)
M2483K /KD : 12 (26.4)
M2485B /BD /H /HD /K /KD : 20 (44.1)
M2485B1 /BD1 /H1 /HD1 /K1 /KD1 : 30 (66.1)
Ambient temperature (operating) : 10ºC to 40ºC
Relative humidity (operating) : 20% to 80% non-condensing
Wet bulb : 29ºC
Altitude (operating) : up to 1,800 metres (6,000 ft)
Power requirements :
DC for for drive unit : +24v (+10%, -7%) 4.0A
+12v ±7% 2.0A
+5v ±5% 16.0A
-5v ±5% 5.0A
AC for optional power supply : 100 to 240 VAC auto switching
Recorded Cartridges
Temperature : 5 to 37 deg C
Humidity : 5 to 80% RH
Max. Wet Bulb : 27 deg. C
Blank Cartridges
Temperature : -23 to 48 deg C
Humidity : 5 to 100% RH
Max. Wet Bulb : 27 deg. C
Safety and EMI Standards
UL 1950
CSA 22.2 No. 950
EN60 950
VCCI Class I
FCC Class A
VDE Class B (conformity)