00000097.gif Fujitsu M2483B /K /N, M2485B /K /N : Switch and Control Panel Settings

Setup

00000130.gif

To set the drive in Test Mode, press RESET to put the drive in the 'not ready' state, press UNLOAD to eject any cartridges. If the automatic cartridge loader is installed then press EJECT and remove the magazine.

Complete MTU Setup Details

Key press sequence                             Display                                                    
                                                                                                          
UNLOAD and TEST                                DIAGMODE                                                   
simultaneously for at least 2 seconds                                                                     
                                                                                                          
START                                          SETTING                                                    
                                                                                                          
START                                          SEL MTC                                                    
                                                                                                          
TEST                                           CTRL OFL  PUSH STR                                         
                                                                                                          
START                                          00:CNFG                                                    
                                                                                                          

Once in 'TEST MODE' the switches operate in the following fashion :

00000093.gif  START                                     Increments the item number                                     
                                                                                                           
00000093.gif  SHIFT + START                             Decrements the item number                                     
                                                                                                           
00000093.gif  TEST                                      Executes the selected function                                 
                                                                                                           
00000093.gif  RESET                                     Cancels the current setting                                    
                                                                                                           

The following items can now be set from the control panel:

0:TMODE            Set the SCSI target mode                                                               
                                                                                                          
1:TADDR            Sets the SCSI target address                                                           
                                                                                                          
2:SDTR             Set the synchronous/asynchronous transfer mode                                         
                                                                                                          
3:PARIT            Enables/disables SCSI bus parity checking                                              
                                                                                                          
4:ASYEN            Sets the UNIT ATTENTION async interrupt mode                                           
                                                                                                          
5:TERM             Displays the SCSI terminator type                                                      
                                                                                                          
6:COMP             Displays data compression status                                                       
                                                                                                          
7:DEVS             Displays the MTU address                                                               
                                                                                                          
8:BAUD             Displays the baud rate of the RS232C                                                   
                                                                                                          
9:XRATE            Sets the SCSI synchronous data transfer goup                                           
                                                                                                          
10:WTNVR           Write the settings to non-volotile RAM                                                 
                                                                                                          
M2483/5

MTU SETTING SPECIFICATION

1. Setting Function

The setting function sets the drive.  The following settings are available:

1. "70:*****" ----- Reserved

2. "71:S.ECL" ----- Sets the EC level.

3. "72:-----" ----- Reserved

4. "73:S.LNG" ----- Sets the display language.

5. "74:S.RDY" ----- Sets whether to display a message when the tape is positioned at beginning of tape (BOT).

6. "75:S.*N " ----- Sets the display of logical addresses.

7. "76:S.ITS" ----- Sets the operator panel intensity.

8. "77:*****" ----- Reserved

9. "78:S.FT1" ----- Sets other additional functions.

10. "79:S.FT2" ----- Sets other additional functions.

11. "80:S.FT3" ----- Sets other additional functions.

12. "81:S.FT4" ----- Sets other additional functions.

13. "83:S.ACL" ----- Sets auto loader mode immediately after power on.

14. "84:*****" ----- Reserved

15. "85:*****" ----- Reserved

16. "86:*****" ----- Reserved

17. "87:F.SET" ----- Factory setting

18. "88:DPSET" ----- Displays setting information.

19. "89:WTROM" ----- Writes setting information to EEPROM.

1.1 Operation Method


(1) Press the UNLOAD switch for two seconds while pressing the TEST

switch to start test mode.

(2) Press the START switch to change the display to SETTING,

then press the TEST switch to enter the setting mode.

(3) Press the START switch to select a setting item.

(4) Press the TEST switch to execute the selected setting item.

See Section 1.2 for details on how to set setting items.

(5) To terminate setting mode and select internal tester mode,

Press the RESET switch when a setting item is selected.

(6) Press the RESET switch during execution of setting interrupt

and select a setting item.

1.2 Setting Routines


This section explains the operation methods related to setting items.

71:S.ECL

Sets the EC level.

The operator panel displays the following item. Press the START

(increment), SHIFT, and START (decrement) switches to select an EC

level, then press the TEST switch to set the EC level.

&quotEC LV:##" ## indicates the EC level represented by a

hexadecimal number.

Note: If the auto loader is mounted, &quotEC LV:01" must be set.

73:S.LNG

Sets the language to be displayed on the operator panel.

The operator panel displays one of the following items.

Press the START switch to select an item, then press the TEST

switch to set the item.

" ENGLISH" English

" FRENCH" French

" GERMAN" German

" SPANISH" Spanish

" ITALIAN" Italian

74:S.RDY

Sets whether to display BOT RDYU and BOT RDYF when the cartridge is loaded.

The operator panel displays one of the following items.

Press the START switch to select an item, then press the TEST switch to set the item.

"BOTRDY:Y" BOT RDY is displayed.

"BOTRDY:N" BOT RDY is not displayed.

75:S.*N

Sets whether to display the logical device address of the drive when the cartridge is not loaded. " *N" is displayed.

(N indicates the logical device address represented by 0 to 3)

The operator panel displays one of the following items.

Press the START switch to select an item, then press the TEST switch to set the item.

" *N :YES" LOGICAL ADDRESS is displayed.

" *N :NO " LOGICAL ADDRESS is not displayed.

76:S.ITS

Sets the operator panel intensity.

The operator panel displays the following item. Press the START switch to change the value of intensity and select the desired value, then press the TEST switch to set the value.

" INTEN:#" # indicates the operator panel intensity

represented by 0 (bright) to 3 (dark)

78:S.FT1

Sets additional functions.

The operator panel displays one of the following items.

Press the START (increment), SHIFT, and START (decrement) switches to select an item, then press the TEST switch to set the item.

" FMOD1:## " # is displayed by a hexadecimal number.

+-------+-------+-------+-------+-------+-------+-------+-------+

| bit 7 | bit 6 | bit 5 | bit 4 | bit 3 | bit 2 | bit 1 | bit 0 |

+-------+-------+-------+-------+-------+-------+-------+-------+

|DISP |RESERVE|RESERVE|RESERVE|RESERVE|EOT |E-CART |WRT RAS|

|KEY | | | | |ALERT |ERR |MASK |

| | | | | | |MASK | |

+-------+-------+-------+-------+-------+-------+-------+-------+

Bit 7: DISP KEY

Setting this bit displays the abbreviation of a switch on the operator panel when it is pressed.

Bit 2: EOT ALERT

Setting this bit alerts the MTC to the EOT area only once.

This mode is used to improve WRITE performance in the EOT area. MTC micro code must support this mode.

Bit 1: E-CART ERR MASK

Setting this bit masks the long-medium reject function.

Bit 0: WRITE RAS MASK

Setting this bit masks WRITE RAS ERROR during execution of WRITE operation in the diagnostic mode.

79:S.FT2

Sets additional functions.

The operator panel displays one of the following items. Press

the START (increment), SHIFT, and START (decrement) switches to select an item, then press the TEST switch to set the item.

" FMOD2:## " # is displayed by a hexadecimal number.

+-------+-------+-------+-------+-------+-------+-------+-------+

| bit 7 | bit 6 | bit 5 | bit 4 | bit 3 | bit 2 | bit 1 | bit 0 |

+-------+-------+-------+-------+-------+-------+-------+-------+

|RESERVE|RESERVE|RESERVE|RESERVE|RESERVE|BUFFER |SEL MTC|FAN |

| | | | | |FLUSH | |FAIL |

| | | | | | | |REPORT |

+-------+-------+-------+-------+-------+-------+-------+-------+

Bit 2: BUFFER FLUSH

Setting this bit places the device in buffer flush mode.

Bit 1: SEL MTC

Setting this bit displays SEL MTC on the menu.

Bit 0: FAN FAIL REPORT

Setting this bit reports a fan failure to the high-order device if it is detected when the cartridge is loaded.

Power to the device is not turned off until the high-order device issues the UNLOAD command. If the UNLOAD command is not issued within about five minutes after the fan failure occurs, the drive unloads the loaded tape and the device is turned off.

80:S.FT3

Sets additional functions.

The operator panel displays one of the following items. Press the START (increment), SHIFT, and START (decrement) switches to select an item, then press the TEST switch to set the item.

" FMOD3:## " # is displayed by a hexadecimal number.

FMOD3:00 Setting when the device is used normally

+-------+-------+-------+-------+-------+-------+-------+-------+

| bit 7 | bit 6 | bit 5 | bit 4 | bit 3 | bit 2 | bit 1 | bit 0 |

+-------+-------+-------+-------+-------+-------+-------+-------+

|RESERVE|AUTO |AUTO |MAG TBL|RESERVE|CLN |AUTO |APR |

| |CLN |CLN |MODE | |OPT |CLN | |

| |MANU |EJECT | | | |MASK | |

| |MSK |MD | | | | | |

+-------+-------+-------+-------+-------+-------+-------+-------+

Bit 6: AUTO CLN MANU MASK

Setting this bit masks the auto cleaning function after manual unloading. (FACL only)

Bit 5: AUTO CLN EJECT MD

Setting this bit performs auto cleaning before the magazine is ejected. (Normally, auto cleaning is performed after unloading. FACL only).

Bit 4: MAG TBL MODE

Setting this bit changes the definition of the magazine table indicated by the sense byte. When the cartridge is loaded, the bit at the position of the loaded magazine is reset. (FACL only. ANSI code is supported.)

Bit 2: CLN OPT

Setting this bit causes the cleaning cell to be unavailable.

(FACL only)

Bit 1: AUTO CLN MASK

Setting this bit masks the auto cleaning function.

(FACL only)

Bit 0: APR

Setting this bit causes auto power-off recovery (APR) mode to be entered. (FACL only)

81:S.FT4

Sets additional functions.

The operator panel displays one of the following items. Press the START (increment), SHIFT, and START (decrement) switches to select an item, then press the TEST switch to set the item.

" FMOD4:## " # is displayed by a hexadecimal number.

+-------+-------+-------+-------+-------+-------+-------+-------+

| bit 7 | bit 6 | bit 5 | bit 4 | bit 3 | bit 2 | bit 1 | bit 0 |

+-------+-------+-------+-------+-------+-------+-------+-------+

|RESERVE|RESERVE|RESERVE|RESERVE|RESERVE|CLN |CLN |CLN |

| | | | | |CELL |CELL |CELL |

| | | | | |bit2 |bit1 |bit0 |

+-------+-------+-------+-------+-------+-------+-------+-------+

Bits 2 to 0: CLN CELL bits 2 to 0

Setting these bits can specify the limit on the use count of the cleaning cartridge in the cleaning cell. A warning message is displayed 10 times before the limit on the use count. (FACL only)

Even if the set limit on the use count is exceeded, the warning message is simply displayed and cleaning is still possible.

Bits 2/1/0

000 : 490 times

001 : 90 times

010 : 190 times

011 : 290 times

100 : 390 times

101 : 590 times

110 : 690 times

111 : 790 times

83:S.ACL

Specifies the auto loader mode immediately after power on when the auto loader is used.

The operator panel displays one of the following items. Press the START switch to select an item, then press the TEST switch

to set the item.

"ACL:AUTO" Auto mode is set immediately after power on.

"ACL:SYS" System mode is set immediately after power on.

87:F.SET

Factory setting

This is a reserved option used to set factory defaults.

88:DPSET

Displays setting information. Press the START switch to display the set data items sequentially on the display. Press the TEST or RESET switch to stop displaying the set data items.

89:WTROM

Writes setting information into nonvolatile ROM (EEPROM).

The operator panel displays one of the following items. Press the START switch to select an item, then press the TEST switch to execute the item.

"WTROM: Y" The set data is written to EEPROM.

"WTROM: N" The set data is not written to EEPROM.

Setting at shipment (MTU)

+-------+-------+

| |M2483 |

| |XY |

| | |

| | |

+-------+-------+

|71: |EC LV: |

|S.ECL |00 |

+-------+-------+

|73: |ENGLISH|

|S.LNG | |

+-------+-------+

|74: |BOTRDY:|

|S.RDY |N |

+-------+-------+

|75:S.*N|*N :NO |

+-------+-------+

|76: |INTEN:0|

|S.ITS | |

+-------+-------+

|78: |FMOD1: |

|S.FT1 |00 |

+-------+-------+

|79: |FMOD2: |

|S.FT2 |02 |

+-------+-------+

|80: |FMOD3: |

|S.FT3 |00 |

+-------+-------+

|81: |FMOD4: |

|S.FT4 |00 |

+-------+-------+

|83: |ACL: |

|S.ACL |AUTO |

+-------+-------+

|A0: |FACT0: |

|S.FA0 |02 |

+-------+-------+

|A1: |FACT1: |

|S.FA1 |00 |

+-------+-------+

|A2: |FACT2: |

|S.FA2 |00 |

+-------+-------+

|A3: |FACT3: |

|S.FA3 |00 |

+-------+-------+

* Set the desktop and standalone devices in the same way as the setting of the rack-mount devices (M2483) to be called from those devices.