00000084.gif Fujitsu M1603T, 1606T Installation

BIOS Parameters                                                                             
                                                                                            
                   Cylinders            Heads             Sectors per Track             
                                                                                        


M1603TAU           1055                 16                63                            
                                                                                        
M1606TAU           2111                 16                63                            
                                                                                        


ORIENTATION

00000167.gif

The drive may be installed in one of three orientations; either PCA down or on either edge. Inclination from vertical or horizontal should not exceed 5°.

MOUNTING SCREW FIXING

00000168.gif

When the mounting screw holes on the side of the drive are used, then use only the two pairs of outer holes. Do not use the centre holes in conjunction with only one of the outer holes. Drives with the suffix TAM accept M3 screws while drives with the suffix TAU accept #632UNC screws. The screw must not penetrate the drive by more than 4 millimetres

GROUNDING

Sufficient grounding will be provided for correct operation when the drive is screwed into an electrically grounded frame.

COOLING

00000169.gif

Allow space above and below the drive to provide for adequate air flow. Fan cooling is recommended. The disk enclosure temperature, measured at top centre, should never exceed 60°C.