Fujitsu M1603T, 1606T Switch & Jumper Settings

00000172.gif

Terminal CNH1

Pins          Status          Function                                                          
                                                                                                

1-2           SHORT*          Select drive as MASTER                                            
              OPEN            Select drive as SLAVE                                             
                                                                                                
3-4           OPEN            RESERVED (do not short)                                           
                                                                                                
5-6           SHORT*          Auto idle control disabled                                        
              OPEN            Auto idle control enabled                                         
                                                                                                
7-8           SHORT           CSEL connected to interface                                       
              OPEN*           CSEL not connected to interface                                   
                                                                                                
9-10          OPEN            RESERVED                                                          
                                                                                                


CSEL provides for an alternative method for selection of the MASTER and SLAVE configurations. A special cable is needed to implement this feature and should only be used if supported by BOTH drives.